Skip to content
Fiscal Receipts

Radiological Control

NRDT&EPartial Reconciliation0603542N
What it is
Radiological Control — a research & development program run by Navy.
What changed
-$71.0K FY25→26
Who gets it
No award linkage at high confidence.

Budget Figures

FY24 Actuals
$808.0K
FY25 Total
$801.0K
FY26 Request
$730.0K
FY25→26 Change
-$71.0K

FY2026 award data is a partial year — USASpending awards are reported on a rolling basis and the fiscal year does not close until September 30. why partial FY2026 data? →

Budget Trajectory
FY24: $808.0KFY25: $801.0KFY26: $730.0KFY24FY25FY26
FY24
$808.0K
FY25
$801.0K
FY26
$730.0K
Decade view — each figure cites its own President's Budget edition
FY2015 actuals — PB2017 editionFY2016 actuals — PB2018 editionFY2017 actuals — PB2019 editionFY2018 actuals — PB2020 editionFY2019 actuals — PB2021 editionFY2020 actuals — PB2022 editionFY2021 actuals — PB2023 editionFY2022 actuals — PB2024 editionFY2023 actuals — PB2025 editionFY2024 actuals — PB2026 editionFY2016 enacted — PB2017 editionFY2017 enacted — PB2018 editionFY2018 enacted — PB2019 editionFY2019 enacted — PB2020 editionFY2020 enacted — PB2021 editionFY2021 enacted — PB2022 editionFY2022 enacted — PB2023 editionFY2023 enacted — PB2024 editionFY2024 enacted — PB2025 editionFY2025 enacted — PB2026 editionFY2017 request — PB2017 editionFY2018 request — PB2018 editionFY2019 request — PB2019 editionFY2020 request — PB2020 editionFY2021 request — PB2021 editionFY2022 request — PB2022 editionFY2023 request — PB2023 editionFY2024 request — PB2024 editionFY2025 request — PB2025 editionFY2026 request — PB2026 editionFY15FY26

● actuals (line)  ·  ○ enacted  ·  ◇ request — gaps are editions the program is absent from, never interpolated.

SeriesFY15FY16FY17FY18FY19FY20FY21FY22FY23FY24FY25FY26
Actuals$667.0K$709.0K$677.0K$716.0K$735.0K$679.0K$745.0K$758.0K$769.0K$808.0K
Enacted$710.0K$702.0K$745.0K$740.0K$689.0K$775.0K$761.0K$772.0K$811.0K$801.0K
Request$702.0K$745.0K$740.0K$689.0K$778.0K$761.0K$772.0K$811.0K$801.0K$730.0K

blank = series not published for this year; – = absent from that edition.

Asked vs spent: the PB2021 book requested $778.0K for FY2021; the PB2023 book reports $745.0K actually spent — $33.0K below the request.

Program Lineage

No predecessor/successor lineage was recorded for this program element — no FY-to-FY transfer into or out of this line was stated in the ingested J-books, and none was inferred from the program structure.

Description

Mission RADIAC Development

Mission: The Radiation Detection, Indication and Computation (RADIAC) Program is responsible for providing radiation monitoring instruments that detect and measure radiation in accordance with the provisions of Title 10 of the Code of Federal Regulations (10 CFR 20). These instruments are used on all vessels afloat and at every shore installation in order to ensure the safety of personnel and the environment. RADIACs are also required after an act of terrorism or war that involves nuclear material in order to enable continuation of warfighting ability. Justification: Many RADIAC instruments and dosimetry systems are decades old and approaching the end of their useful lives. In some cases the equipment and replacement parts are no longer manufactured, making the equipment logistically unsupportable. In other cases increasing failure rates due to age make replacements an economic efficiency improvement. In all cases a technology refresh will make both economic sense in terms of lowering the total ownership costs, and will also provide increased operational capabilities. Naval Nuclear Propulsion Program (NNPP): Instruments are developed to support the safe operation and maintenance of nuclear powered vessels and at nuclear maintenance facilities. Non-NNPP: Instruments are developed to support other than NNPP end users, such as Explosive Ordnance Disposal, Nuclear Weapons, Medical, Industrial Radiography, Radiological Defense and Training. Visit, Board, Search & Seizure (VBSS): The Navy has been tasked to intercept and board vessels at sea to search for nuclear or radiological materials that could be used for terrorist attacks. These instruments would have different characteristics than those used for NNPP and non-NNPP purposes and prototypes must be developed and/or tested and evaluated.

Mission Radiological Control

Mission Description: The Radiation Detection, Indication and Computation (RADIAC) Program is responsible for providing radiation monitoring instruments that detect and measure ionizing radiation. These instruments are used on all Navy, Coast Guard and Military Sealift Command vessels, and at every Navy shore installation, in order to ensure the safety of personnel, continuity of operations in radiological contingencies, and protection of the environment. Justification: Title 10 of the Code of Federal Regulations, Part 20 (10 CFR 20) requires RADIAC instruments be used to ensure the safety of personnel who work with or who are exposed to radioactive materials in their jobs. Additionally, the Navy's mission requires personnel and ships to have the ability to operate in radiological environments and the ability to identify and interdict radiological Weapons of Mass Destruction (WMD). Navy programs that require RADIAC instruments for Occupational Safety & Health (OSH) under the provisions of 10 CFR 20 include Naval Nuclear Propulsion, Nuclear Weapons, Medical, and Radiological Affairs Support. Non-OSH programs include Radiological Defense, Consequence Management, Training, Technical (RADIAC calibration, shielding evaluation, research) and Radiological Search (maritime interdiction and radiological search missions to locate or intercept WMD). This budget item develops, tests and evaluates new, highly reliable, more easily calibrated, easy to care and maintain, light weight and modern RADIAC instruments in order to improve the effectiveness of radiation safety, to make instruments simpler to use, and to reduce life cycle costs. The ultimate goal is to replace old, bulky, costly to maintain and repair, unreliable and obsolete instrumentation with multifunction equipment that can be automatically calibrated at greatly reduced cost.

Justification

Accomplishments & Planned Programs (6)

Laboratory Test Equipment

Laboratory Test Equipment are used in laboratories to test and evaluate radiation detectors and dosimetry devices. The primary end users will be NSWCCD and NDC. The beta irradiators will be used throughout the development and procurement of the Navy's new primary dosimetry system to evaluate system performance. Handheld radiation detection equipment from the Radiological Detection System (RDS) can also be evaluated using the beta irradiators. The upgraded Ortec equipment will be used to analyze the new accident dosimeter after exposure to a criticality event.

Primary Dosimetry

The need for primary dosimetry is inherent due to the Navy's operation of nuclear reactors and their emission of ionizing radiation. Title 10 CFR 20.1502 states "Each licensee shall monitor exposures to radiation and radioactive material at levels sufficient to demonstrate compliance with the occupational dose limits." A primary dosimeter must pass accreditation proficiency testing, allowing the reading obtained to become a part of an individual's permanent health record. This permanent record is used to protect the individual radiation worker's health, and also the Navy from future liability. The Navy's current primary device is the DT-702/PD, a passive Thermo Luminescence Dosimeter (TLD). Existing TLDs and newer technologies, such as Optically Stimulated Luminescence (OSL), must be continually researched to determine on-going performance parameters, cost to field and cost to maintain, since the current system is approaching the end of its useful life and must be replaced by 2030. A passive device does not provide a display of the dose being received, which can be important in certain circumstances. The dosimeter instead must be sent to a facility with a special reader to recover the dose, which is then entered in the individual's medical records. An active device displays the dose digitally in real time, providing immediate feedback in high risk scenarios. Newer passive-active systems can do both.

Radiological Detection System Training Device

The Radiological Detection System (RDS) is a survey meter with ancillary probes that is being procured by all the Services and some North Atlantic Treaty Organization (NATO) allies to replace the legacy equipment in all the respective procuring activities, and to allow joint interoperability. The Training Device will be an instrument designed to simulate the detection and measurement of alpha, beta, gamma, neutron and low energy X-rays for trainees on the RDS equipment without having to use actual radioactive sources. This makes the training safer and more cost effective to manage by avoiding the significant legal and safety issues involved when using radioactive sources.

Battery Powered Air Particle Sampler

The HD-11510 is a battery powered portable air article sampler used for radioiodine sampling by the Naval Nuclear Propulsion Program (NNPP). The HD-11510 has been fielded for over 15 years. The weight of the device at 38 pounds has been a long-standing complaint by the end user community. The solution is to replace the HD-11510, or potentailly redesign the battery compartment of the existing device. Naval Surface Warfare Center Carderock Division (NSWCCD) will research four possible replacements for the HD-11510.

Secondary Dosimetry

Secondary dosimetry includes the monitoring of doses to the hands, feet and eyes. In some medical and industrial applications, there is a high risk of such local high exposures due to the handling of sources, working close to a high radiation field, or using/cleaning high-energy beta emitters. Because of this, the need to accurately measure extremity dose is of significant importance to the Navy. The legacy system currently used for hands and feet dose measurements is RadStar. This is an active system (see the Primary Dosimetry Overall Description task for a discussion of passive and active dosimeters), but it is no longer supported by the vendor and must be replaced. To that end the ED3 system was procured in FY18 and has been tested and a report rendered on its suitability as a replacement. This is another active system, but shortfalls noted were that it currently measures only exposure to the hands, and it is too fragile for industrial-type use. Another active system being considered is the iMUX, which has the advantage of being wireless (the other two require wires that extend from the extremities to a pager-sized device clipped to the belt or worn on the wrist), and is capable of measuring dose at both the hands and feet. Measurement of dose at the eyes is currently extrapolated from the Navy's passive primary dosimeter, the DT-702/PD. Because eyes are subject to development of cataracts with prolonged or high dose exposure to radiation, a more precise and real time measuring device is being sought in the systems being evaluated. A secondary dosimeter provides an accurate, real-time readout of the radiation exposure in operational environments and is utilized in conjunction with a primary dosimeter. Employment of extremity monitoring can be utilized during operations requiring hands-on maintenance in a radiation field, research facilities and medical procedures. A replacement EPD that can function as both a secondary and extremity dosimeter will be used by NNPP, RASO, BUMED and SSP during everyday operations and will be replacing the current ThermoFisher Scientific (TFS) MK-2 and RADSTAR systems.

Surface Contamination Monitor

A Surface Contamination Monitor (SCM) will allow the end user to quickly survey large areas for alpha-beta contamination. These types of surveys are required by federal, state and Navy regulations prior to releasing an area for unlimited use. SCM technology configurations include proportional detectors or scintillation type detectors. In addition, the SCM automated mapping and report generating features will accelerate these types of radiological surveys. These devices would be used at shipyard facilities by the Naval Nuclear Propulsion Program.

Budget Line Items(workbook-cited)

Exhibit R-1

AccountOrgTypeAmount
Research, Development, Test and Evaluation, NavyNFY24 Actuals$808.0K
Research, Development, Test and Evaluation, NavyNFY25 Enacted$801.0K
Research, Development, Test and Evaluation, NavyNFY25 Total$801.0K
Research, Development, Test and Evaluation, NavyNFY26 Disc. Request$730.0K
Research, Development, Test and Evaluation, NavyNFY26 Total$730.0K

Budget Details(R-2/P-40 facts)

ProjectAll Prior YearsFY24 ActualsFY25 TotalFY26 BaseFY26 Request
Program Element$8.78M$808.0K$801.0K$730.0K$730.0K
1830: RADIAC Development$8.78M$808.0K$801.0K$730.0K$730.0K

No follow-the-dollar view — this program's awards haven't been crosswalked at high confidence (flows cover 17 of 1741 programs). why coverage is partial? →

Awards

No awards are linked to this program element at high confidence — the budget→award crosswalk only asserts links it can defend, and this line has none yet.

Lobbying Mentions

No Senate LDA lobbying filing in the tracked data mentions this program element by code or alias.

No research dossier for this program — dossiers cover 50 of 1741 programs, the largest fully J-book-detailed lines by FY2026 requested dollars. why no dossier here? →